TABLE D-13 - TUBE AND COUPLER SCAFFOLDS - LIGHT DUTY
_______________________________________________________________
|
Uniformly distributed load............| Not to exceed 25 p.s.f.
Post spacing (longitudinal)...........| 10 ft. 0 in.
Post spacing (transverse).............| 6 ft. 0 in.
______________________________________|________________________
_______________________________________________________________
| |
| Additional planked |
Working levels| levels | Maximum height
___________________|______________________|____________________
| |
1 | 8 | 125 ft.
2 | 4 | 125 ft.
3 | 0 | 91 ft. 0 in.
___________________|______________________|____________________
TABLE D-14 - TUBE AND COUPLER SCAFFOLDS - MEDIUM DUTY
_______________________________________________________________
|
Uniformly distributed load............| Not to exceed 50 p.s.f.
Post spacing (longitudinal)...........| 8 ft. 0 in.
Post spacing (transverse).............| 6 ft. 0 in.
______________________________________|________________________
_______________________________________________________________
| |
| Additional planked |
Working levels| levels | Maximum height
___________________|______________________|____________________
| |
1 | 6 | 125 ft.
2 | 0 | 78 ft. 0 in.
___________________|______________________|____________________